PE-GC6V 6V Deep Cycle Flooded Battery

Model PE-GC6V · Flooded Deep Cycle Batteries

A 6-volt, 232 Ah (20-hr) flooded lead acid deep cycle battery in the BCI GC2 golf cart group size, delivering 474 minutes of reserve capacity at 25 A. Built for golf cars, floor care machines, aerial work platforms, renewable energy storage, and utility vehicles.

Voltage
6 V (nominal)
Capacity (20-hr rate)
232 Ah
Weight (wet)
62 lb (28 kg)
BCI Group Size
GC2

Features

  • Deep cycle flooded lead acid (FLA), non-sealed construction
  • 3-cell, 6-volt design in BCI Group GC2 footprint
  • Heat-sealed polypropylene case
  • Molded-In UTL terminals with stainless steel hardware
  • Standard vent caps, bayonet caps optional
  • 1.270 minimum specific gravity at full charge
  • Suited for golf cars, floor care, aerial work platforms, renewable energy storage, and utility vehicles/RV

Technical Specifications

Electrical
Voltage 6 V (nominal)
BCI Group Size GC2
Type Flooded lead acid (FLA), non-sealed, deep cycle
Number of Cells 3
Capacity Ratings
Capacity (20-hr rate) 232 Ah
Capacity (1-hr rate) 133 Ah
Capacity (2-hr rate) 152 Ah
Capacity (5-hr rate) 181 Ah
Capacity (6-hr rate) 187 Ah
Capacity (10-hr rate) 206 Ah
Capacity (48-hr rate) 246 Ah
Capacity (72-hr rate) 252 Ah
Capacity (100-hr rate) 258 Ah
Reserve Capacity @ 25 A 474 min
Reserve Capacity @ 56 A 175 min
Reserve Capacity @ 75 A 122 min
Mechanical
Length 10-1/4 in (260 mm)
Width 7-1/8 in (181 mm)
Height 11-1/4 in (286 mm)
Weight (wet) 62 lb (28 kg)
Terminal Type Molded-In UTL
Terminal Torque 95-105 in-lb (7.9-8.8 ft-lb)
Connection Hardware Stainless steel hexnut with SS split-ring lock washer (5/16" positive and negative)
Case Material Polypropylene, heat sealed
Specific Gravity at Full Charge 1.270 minimum
Vent Cap Standard, bayonet optional
Charging & Temperature
Charge Profile - Bulk 7.35 ± 0.15 V at 23.2 A to setpoint
Charge Profile - Absorption 7.35 V, taper to 7.0 A, 2-3 hr
Charge Profile - Float (optional) 6.51 V, unlimited duration
Charge Profile - Equalize 7.65 ± 0.15 V, 1-3 hr every 30 days
Charge Time from Full Discharge 9-12 hr
Charge Termination Time (2-4 hr) or dV/dt 4 mV/cell/hr
Temperature Correction -0.084 V per 10 °F above 80 °F
Charging Temperature Range 0 to 120 °F (-18 to 49 °C)
Discharging Temperature Range -20 to 120 °F (-29 to 49 °C)
Equalization Interval Every 30 days in active service
Applications
Typical Applications Golf cars, floor care, aerial work platforms, renewable energy storage, utility vehicles and RV

Download the full data sheet (PDF)

Get the PE-GC6V From a Local Dealer

Our nationwide dealer network provides sales, installation and support.

Find a Dealer Register Your Warranty